Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://dspace.opu.ua/jspui/handle/123456789/15187
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorShcherbakova, Galyna-
dc.contributor.authorЩербакова, Галина Юріївнa-
dc.contributor.authorAntoshchuk, Svitlana-
dc.contributor.authorАнтощук, Світлана Григорівна-
dc.contributor.authorSachenko, Anatoliy-
dc.contributor.authorСаченко, Анатолій Олексійович-
dc.contributor.authorVolkova, Nataliia-
dc.contributor.authorВолкова, Наталія Павлівна-
dc.contributor.authorRusyn, Bohdan-
dc.contributor.authorРусин, Богдан Георгійович-
dc.contributor.authorRippa, Sergii-
dc.contributor.authorРіппа, Сергій Петрович-
dc.date.accessioned2025-05-16T10:49:02Z-
dc.date.available2025-05-16T10:49:02Z-
dc.date.issued2023-
dc.identifier.citationShcherbakova, G., Antoshchuk, S., Sachenko, A., Volkova, N., Rusyn, B., Rippa, S. (2023). Increasing the accuracy of determining RR intervals of ECG using wavelet transform. Proceedings of the IEEE International Conference on Intelligent Data Acquisition and Advanced Computing Systems: Technology and Applications, IDAACS, P. 1219-1222.en
dc.identifier.issn27704262-
dc.identifier.urihttp://dspace.opu.ua/jspui/handle/123456789/15187-
dc.description.abstractThe paper presents a technique for calculation of coordinate values of the extremum of electrocardiograms signals based on wavelet transform optimization. The procedures for evaluating of the coordinates of R waves and the intervals between them for electrocardiograms based on the search with the Haar wavelet function are given. The such parameters calculation error under conditions of noise levels is studied. The influence of the length of the support of the Haar wavelet function and the step size on the speed of the search is estimated.en
dc.language.isoenen
dc.publisherInstitute of Electrical and Electronics Engineers Inc.en
dc.subjectoptimizationen
dc.subjectwavelet transformen
dc.subjectelectrocardiogramen
dc.subjectarrhythmiaen
dc.subjectdiagnosticsen
dc.titleIncreasing the accuracy of determining RR intervals of ECG using wavelet transformen
dc.typeArticle in Scopusen
opu.citation.journalProceedings of the IEEE International Conference on Intelligent Data Acquisition and Advanced Computing Systems: Technology and Applications, IDAACSen
opu.citation.firstpage1219en
opu.citation.lastpage1222en
Располагается в коллекциях:2023

Файлы этого ресурса:
Файл Описание РазмерФормат 
IDAACS_2023_CameraReady_328.pdf540.86 kBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.